Move Ref-Data & Add my first shot
Before Width: | Height: | Size: 112 KiB After Width: | Height: | Size: 112 KiB |
Before Width: | Height: | Size: 116 KiB After Width: | Height: | Size: 116 KiB |
Before Width: | Height: | Size: 114 KiB After Width: | Height: | Size: 114 KiB |
Before Width: | Height: | Size: 140 KiB After Width: | Height: | Size: 140 KiB |
Before Width: | Height: | Size: 121 KiB After Width: | Height: | Size: 121 KiB |
20
data/x2s5823/_info.yaml
Normal file
@ -0,0 +1,20 @@
|
||||
long_name: "Shot 1 - Fat Probe - 2024-10-15"
|
||||
name: "Shot 1"
|
||||
date: "2024-10-15"
|
||||
|
||||
shot-info:
|
||||
name: "x2s5823"
|
||||
|
||||
probe-info:
|
||||
type: "Fat"
|
||||
c2c: 5.6 # mm
|
||||
gauge-diam: 3.05 # mm
|
||||
gauge-c2c: 4 #mm
|
||||
data-record:
|
||||
type: "scope"
|
||||
config: "eProbe-Scope.txt"
|
||||
data-file: "eProbe-Scope.csv"
|
||||
trigger:
|
||||
type: "scope"
|
||||
delay: 0
|
||||
|
7682
data/x2s5823/eProbe-Scope.csv
Normal file
24
data/x2s5823/eProbe-Scope.txt
Normal file
@ -0,0 +1,24 @@
|
||||
ANALOG
|
||||
Ch 1 Scale 200mV/, Pos 185.00mV, Coup DC, BW Limit Off, Inv Off, Imp 1M Ohm
|
||||
Probe 10.000000 : 1, Skew 0.0s
|
||||
Ch 2 Scale 200mV/, Pos 177.00mV, Coup DC, BW Limit Off, Inv Off, Imp 1M Ohm
|
||||
Probe 10.000000 : 1, Skew 0.0s
|
||||
Ch 4 Scale 1.00V/, Pos 1.93700V, Coup DC, BW Limit Off, Inv Off, Imp 1M Ohm
|
||||
Probe 1.0000000 : 1, Skew 0.0s
|
||||
|
||||
TRIGGER
|
||||
Sweep Mode Auto, Coup DC, Noise Rej Off, HF Rej Off, Holdoff 40.0ns
|
||||
Mode Edge, Source Ch 4, Slope Rising, Level 1.00000V
|
||||
|
||||
HORIZONTAL
|
||||
Mode Normal, Ref Center, Main Scale 500.0us/, Main Delay -100.000000us
|
||||
|
||||
ACQUISITION
|
||||
Mode High Res, Realtime On, Vectors On, Persistence Off
|
||||
|
||||
MEASUREMENTS
|
||||
Average - Full Screen(1), Cur -7.5mV
|
||||
Average - Full Screen(2), Cur >-4.3mV
|
||||
Average - Full Screen(3), Cur No signal
|
||||
Average - Full Screen(4), Cur 2.3810V
|
||||
|
BIN
data/x2s5823/x2s5823.cfg
Normal file
48
data/x2s5823/x2s5823.config
Normal file
@ -0,0 +1,48 @@
|
||||
# x2s5823 config file
|
||||
# This files contains a text version of the National Instruments PXI unit configuration data.
|
||||
# Channels are represented as one line per configured signal with tab-separated values.
|
||||
#
|
||||
# Line content and types of values (first item is item 0):
|
||||
# i item type comments
|
||||
# --------------------------------------------------------------------------------------------------------
|
||||
# 0 signal name string
|
||||
# 1 channel ID string legacy I/O channel designation
|
||||
# 2 external gain float 1 if there is no external amplifier connected
|
||||
# 3 sensitivity float volts per measured unit (of the transducer)
|
||||
# 4 units string name of units for physical quantity (e.g. kPa)
|
||||
# 5 position float position of transducer (in mm)
|
||||
# 6 serial number string transducer identity
|
||||
# 7 PXI channel ID string non-legacy channel ID and trigger source
|
||||
#---------------------------------------------------------------------------------------------------------
|
||||
|
||||
sd1 2 0 9 1 9.500000E-4 kPa 0.000 112A24-9609 PXI1Slot2/ai0
|
||||
sd2 2 1 9 1 9.500000E-4 kPa 0.000 113A22-9535 PXI1Slot2/ai1
|
||||
sd3 2 3 9 1 6.820000E-4 kPa 0.000 112A24-2676 PXI1Slot2/ai3
|
||||
st1 2 4 9 1 1.482000E-2 kPa 0.000 112A22-35071 PXI1Slot2/ai4
|
||||
st2 5 4 9 1 1.168700E-2 kPa 0.000 112A22-35070 PXI1Slot5/ai4
|
||||
st3 2 6 9 1 1.450000E-2 kPa 0.000 112A22-19126 PXI1Slot2/ai6
|
||||
at1 3 0 9 1 1.443000E-2 kPa 0.000 112A22-35098 PXI1Slot3/ai0
|
||||
at2 3 1 9 1 1.450000E-2 kPa 0.000 112A22-9050 PXI1Slot3/ai1
|
||||
at3 3 2 9 1 1.447980E-2 kPa 0.000 112A22-19124 PXI1Slot3/ai2
|
||||
at4 3 3 9 1 1.435000E-2 kPa 0.000 112A22-34424 PXI1Slot3/ai3
|
||||
at5 3 4 9 1 1.447000E-2 kPa 0.000 112A22-34425 PXI1Slot3/ai4
|
||||
at6 3 5 9 1 1.442000E-2 kPa 0.000 112A22-34426 PXI1Slot3/ai5
|
||||
at7 2 7 9 1 1.451000E-2 kPa 0.000 112A22-35096 PXI1Slot2/ai7
|
||||
at8 3 7 9 1 1.490000E-2 kPa 0.000 112A22-35079 PXI1Slot3/ai7
|
||||
pimax4 5 1 9 1 1.000000E-3 mV 0.000 pimax4 PXI1Slot5/ai1
|
||||
trigbox 5 7 9 1 1.000000E-3 mV 0.000 trigbox PXI1Slot5/ai7(Trigger)
|
||||
trigbox_delay 5 5 9 1 1.000000E-3 mV 0.000 trigbox_delay PXI1Slot5/ai5
|
||||
pt1 5 2 9 1 8.500000E-4 kPa 0.000 SN-22554 PXI1Slot5/ai2
|
||||
irc800 8 4 9 1 1.000000E-3 mV 0.000 irc800 PXI1Slot8/ai4
|
||||
shimadzu 8 6 9 1 1.000000E-3 mV 0.000 shimadzu PXI1Slot8/ai6
|
||||
pimax3 8 7 9 1 1.000000E-3 mV 0.000 pimax3 PXI1Slot8/ai7
|
||||
Phantom 8 2 9 1 1.000000E-3 mV 0.000 phantom PXI1Slot8/ai2
|
||||
pt2 6 1 9 1 1.440000E-3 kPa 0.000 SN 22556 PXI1Slot6/ai1
|
||||
pt3 6 2 9 1 1.810000E-3 kPa 0.000 SN 7446 PXI1Slot6/ai2
|
||||
pt4 6 3 9 1 7.300000E-4 kPa 0.000 SN LW30649 PXI1Slot6/ai3
|
||||
pt5 8 3 9 1 7.350000E-4 kPa 0.000 SN LW30651 PXI1Slot8/ai3
|
||||
pt6 6 5 9 1 7.290000E-4 kPa 0.000 SN LW30652 PXI1Slot6/ai5
|
||||
pt7 6 6 9 1 7.220000E-4 kPa 0.000 SN 22514 PXI1Slot6/ai6
|
||||
pt8 3 6 9 1 1.430000E-3 kPa 0.000 SN 16785 PXI1Slot3/ai6
|
||||
pt9 5 0 9 1 1.010000E-3 kPa 0.000 SN 7430 PXI1Slot5/ai0
|
||||
photodiode 8 0 9 1 1.000000E+0 mV 0.000 photodiode PXI1Slot8/ai0
|
20024
data/x2s5823/x2s5823.lvm
Normal file
BIN
data/x2s5823/x2s5823.tdms
Normal file
BIN
data/x2s5823/x2s5823.tdms_index
Normal file
157
data/x2s5823/x2s5823.txt
Normal file
@ -0,0 +1,157 @@
|
||||
--------------------------------------------------------------------------------
|
||||
Project.........................................Mars entry non-equilibrium expanding flows
|
||||
Run number................................ x2s5822
|
||||
Date............................................10/10/2024
|
||||
Blame...........................................Mragank, Matt
|
||||
Condition................................... Mars condition, high density, Mars mixture
|
||||
Reservoir..................................... 6.75 MPa
|
||||
Driver............................................83520 Pa 90% He, 92.8 kPa Argon
|
||||
Primary diaphragm.................... 2 mm scored, cold rolled steel 6U374
|
||||
Shock tube................................... 13000 Pa ( Mars mixture)
|
||||
Secondary diaphragm................ 10 micron mylar
|
||||
Acceleration tube....................... 650 Pa lab air (set on new gauge on the bottom of the dump tank)
|
||||
Trig.............................................. Pt5 (changed as wedge is ahead of pitot probes) slot8ai3 on tee piece 8ai4 - cable pt5
|
||||
Lab environment...................... N/A
|
||||
Driver Condition........................x2-lwp-2.0-90-0
|
||||
|
||||
|
||||
|
||||
|
||||
--------------------------------------------------------------------------------
|
||||
EXPERIMENT SETUP
|
||||
|
||||
pitot rake
|
||||
|
||||
|
||||
|
||||
--------------------------------------------------------------------------------
|
||||
EQUIPMENT
|
||||
--------------------------------------------------------------------------------
|
||||
|
||||
1x photodiode (350 - 1100nm)
|
||||
1xShimadzu -- in use
|
||||
1xmini-spec (200-1000nm)
|
||||
Phantom
|
||||
|
||||
|
||||
|
||||
-------------------------- SUSS Spectral Overview ----------------------------
|
||||
--------------------------------------------------------------------------------
|
||||
Dichroic 1 (UV/VIS): DMLP650L
|
||||
Dichroic 2 (VIS/IR): DMLP900L
|
||||
UV FOV: 8mm
|
||||
VIS FOV: 8mm
|
||||
IR FOV: 8mm
|
||||
|
||||
--------------------------------------------------------------------------------
|
||||
---UV---
|
||||
--------------------------------------------------------------------------------
|
||||
N/A
|
||||
|
||||
--------------------------------------------------------------------------------
|
||||
---Visible---
|
||||
--------------------------------------------------------------------------------
|
||||
Spectrometer: Acton Spectrapro 2300i
|
||||
Centre Wavelength: 775
|
||||
Grating: 150
|
||||
Camera: PIMAX4
|
||||
Gain: 50
|
||||
Delay: 80 us
|
||||
Exposure: 50 us
|
||||
Trigger level: 1V
|
||||
Slit: 100 um
|
||||
Filter:
|
||||
Trigger: A3 cable from trigger box port 0
|
||||
Monitor: T1 Cable
|
||||
Aperture: 12.5 mm
|
||||
|
||||
--------------------------------------------------------------------------------
|
||||
---IR---
|
||||
--------------------------------------------------------------------------------
|
||||
Spectrometer: Acton Spectrapro 2500
|
||||
Centre Wavelength: 1300
|
||||
Grating: 75
|
||||
Camera: IRC800
|
||||
Delay: 100us setted in DAQ with 800 counts
|
||||
Exposure: 20 us
|
||||
Slit: 1000 um
|
||||
Filter:
|
||||
Trigger: T2 cable from trigger box port1
|
||||
Monitor: PDTP1G Cable
|
||||
Aperture: 12.5 mm
|
||||
|
||||
--------------------------------------------------------------------------------
|
||||
|
||||
--------------------------------------------------------------------------------
|
||||
Shimadzu
|
||||
--------------------------------------------------------------------------------
|
||||
|
||||
Window : BK7 Diam 209mm top
|
||||
Lens: Nikon AF Micro NIKKOR 200MM with 780-unknown? filter
|
||||
Aperture-Number 16
|
||||
Frame Rates 500.000 kFPS
|
||||
Exposure: 1/2
|
||||
Gain: x2(/x50)
|
||||
Mode: External
|
||||
Trigger @: 0/0 (0-99=100frames)
|
||||
point: 10
|
||||
Delay: 0 microseconds
|
||||
Polarity: Pos
|
||||
Monitor Expose: off
|
||||
Filter:
|
||||
Cables: Trigger: H6 cable from trigger box port 1
|
||||
Monitor: H4 Cable
|
||||
|
||||
--------------------------------------------------------------------------------
|
||||
PHOTODIODE
|
||||
--------------------------------------------------------------------------------
|
||||
Location: Circle around stagnation point, pt5.
|
||||
Filter: 777nm hydrogen filter actually. not sure which one...
|
||||
Model number: (350-1100)
|
||||
Lens: Unknown
|
||||
Gain: 70
|
||||
Fibre optic cable: Red
|
||||
Aperture: None
|
||||
BNC: A4
|
||||
|
||||
--------------------------------------------------------------------------------
|
||||
MINI-SPEC (200 - 1000nm)
|
||||
--------------------------------------------------------------------------------
|
||||
Location: Pt5 looking out into the flow
|
||||
Filter: none
|
||||
Window: 3mm fused silica from OGP optics.
|
||||
Cable: New red cable
|
||||
Lens: N/A
|
||||
Delay: 80 us + 8 us internal
|
||||
Integration time: 20 us
|
||||
Aperture: N/A
|
||||
Trigger level: 1 V
|
||||
Filter: N/A
|
||||
Trigger: A5 cable from trigger box port 0, with vis
|
||||
|
||||
--------------------------------------------------------------------------------
|
||||
Phantom
|
||||
--------------------------------------------------------------------------------
|
||||
|
||||
Window : side
|
||||
Lens: Nikon AF Micro NIKKOR 105 mm focus
|
||||
Aperture-Number 18
|
||||
Frame Rates 110000.000 FPS
|
||||
Exposure: 1 us
|
||||
Gain: N/A
|
||||
Mode: External
|
||||
Delay: 0 microseconds
|
||||
Polarity: Pos
|
||||
Monitor Expose: off
|
||||
Filter:
|
||||
Cables: Trigger: B3 cable from trigger box port 2
|
||||
Monitor: H4 Cable
|
||||
|
||||
|
||||
LOG
|
||||
X2s5815
|
||||
Bad shot - very messy - oring ruptured in the secondary may have over pressurised with additional LAB Air.
|
||||
X2s5816
|
||||
Fired at 1.32Pa instead of 13.2pa.....
|
||||
|
||||
|