Add referance data & x2s5829
This commit is contained in:
		
							
								
								
									
										38
									
								
								data/x2s5829/_info.yaml
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										38
									
								
								data/x2s5829/_info.yaml
									
									
									
									
									
										Normal file
									
								
							@@ -0,0 +1,38 @@
 | 
			
		||||
# Data Info File
 | 
			
		||||
# Cal Wing - Oct 24
 | 
			
		||||
 | 
			
		||||
long_name: "Shot 4 (x2s5829) - Thin Probe Pair (ST2 & ST3) - 2024-10-17"
 | 
			
		||||
name: "Shot 4"
 | 
			
		||||
date: "2024-10-17"
 | 
			
		||||
time: "17:00"
 | 
			
		||||
 | 
			
		||||
shot-info: 
 | 
			
		||||
  name: "x2s5829"
 | 
			
		||||
  tdms: "x2s5829.tdms"
 | 
			
		||||
  config: "x2s5829.config"
 | 
			
		||||
  info: "x2s5829.txt"
 | 
			
		||||
 | 
			
		||||
pcb-refs:
 | 
			
		||||
  - "st1"
 | 
			
		||||
 | 
			
		||||
probe-info:
 | 
			
		||||
  type: "Thin"
 | 
			
		||||
  locations: # In order of pulse
 | 
			
		||||
    - "st2"
 | 
			
		||||
    - "st3"
 | 
			
		||||
  overhang: 1 # mm
 | 
			
		||||
  c2c: 5.6 # mm
 | 
			
		||||
  gauge-diam: 0.8 # mm
 | 
			
		||||
  gauge-c2c: 1.8 #mm
 | 
			
		||||
  data-record:
 | 
			
		||||
    type: "scope"
 | 
			
		||||
    config: "eProbe-Scope.txt"
 | 
			
		||||
    data: "eProbe-Scope.csv"
 | 
			
		||||
    
 | 
			
		||||
    trigger: # Redundant?
 | 
			
		||||
      type: "channel"
 | 
			
		||||
      channel: 4
 | 
			
		||||
      alignment-offset: 0 # 601 # us [TODO] Make this auto-magic
 | 
			
		||||
      delay: 100 # us
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
							
								
								
									
										7682
									
								
								data/x2s5829/eProbe-Scope.csv
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										7682
									
								
								data/x2s5829/eProbe-Scope.csv
									
									
									
									
									
										Normal file
									
								
							
										
											
												File diff suppressed because it is too large
												Load Diff
											
										
									
								
							
							
								
								
									
										18
									
								
								data/x2s5829/eProbe-Scope.txt
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										18
									
								
								data/x2s5829/eProbe-Scope.txt
									
									
									
									
									
										Normal file
									
								
							@@ -0,0 +1,18 @@
 | 
			
		||||
ANALOG
 | 
			
		||||
Ch 1 Scale 500mV/, Pos 1.25000V, Coup DC, BW Limit Off, Inv Off, Imp 1M Ohm
 | 
			
		||||
     Probe 10.000000 : 1, Skew 0.0s
 | 
			
		||||
Ch 2 Scale 500mV/, Pos 1.25000V, Coup DC, BW Limit Off, Inv Off, Imp 1M Ohm
 | 
			
		||||
     Probe 10.000000 : 1, Skew 0.0s
 | 
			
		||||
Ch 4 Scale 1.00V/, Pos 2.85000V, Coup DC, BW Limit Off, Inv Off, Imp 1M Ohm
 | 
			
		||||
     Probe 1.0000000 : 1, Skew 0.0s
 | 
			
		||||
 | 
			
		||||
TRIGGER
 | 
			
		||||
Sweep Mode Auto, Coup DC, Noise Rej Off, HF Rej Off, Holdoff 40.0ns
 | 
			
		||||
Mode Edge, Source Ch 4, Slope Rising, Level 1.00000V
 | 
			
		||||
 | 
			
		||||
HORIZONTAL
 | 
			
		||||
Mode Normal, Ref Center, Main Scale 500.0us/, Main Delay -100.000000us
 | 
			
		||||
 | 
			
		||||
ACQUISITION
 | 
			
		||||
Mode High Res, Realtime On, Vectors On, Persistence Off
 | 
			
		||||
 | 
			
		||||
							
								
								
									
										
											BIN
										
									
								
								data/x2s5829/x2s5829.cfg
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										
											BIN
										
									
								
								data/x2s5829/x2s5829.cfg
									
									
									
									
									
										Normal file
									
								
							
										
											Binary file not shown.
										
									
								
							
							
								
								
									
										49
									
								
								data/x2s5829/x2s5829.config
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										49
									
								
								data/x2s5829/x2s5829.config
									
									
									
									
									
										Normal file
									
								
							@@ -0,0 +1,49 @@
 | 
			
		||||
# x2s5829 config file
 | 
			
		||||
# This files contains a text version of the National Instruments PXI unit configuration data.
 | 
			
		||||
# Channels are represented as one line per configured signal with tab-separated values.
 | 
			
		||||
#
 | 
			
		||||
# Line content and types of values (first item is item 0):
 | 
			
		||||
# i  item            type        comments
 | 
			
		||||
# --------------------------------------------------------------------------------------------------------
 | 
			
		||||
# 0  signal name     string    
 | 
			
		||||
# 1  channel ID      string    legacy I/O channel designation
 | 
			
		||||
# 2  external gain   float     1 if there is no external amplifier connected
 | 
			
		||||
# 3  sensitivity     float     volts per measured unit (of the transducer)
 | 
			
		||||
# 4  units           string    name of units for physical quantity (e.g. kPa)
 | 
			
		||||
# 5  position        float     position of transducer (in mm)
 | 
			
		||||
# 6  serial number   string    transducer identity 
 | 
			
		||||
# 7  PXI channel ID  string    non-legacy channel ID and trigger source
 | 
			
		||||
#---------------------------------------------------------------------------------------------------------
 | 
			
		||||
 | 
			
		||||
sd1            	2 0 9	     1	9.500000E-4	kPa	0.000	112A24-9609    	PXI1Slot2/ai0	
 | 
			
		||||
sd2            	2 1 9	     1	9.500000E-4	kPa	0.000	113A22-9535    	PXI1Slot2/ai1	
 | 
			
		||||
sd3            	2 3 9	     1	6.820000E-4	kPa	0.000	112A24-2676    	PXI1Slot2/ai3	
 | 
			
		||||
st1            	2 4 9	     1	1.482000E-2	kPa	0.000	112A22-35071   	PXI1Slot2/ai4	
 | 
			
		||||
st2            	5 4 9	     1	1.168700E-2	kPa	0.000	112A22-35070   	PXI1Slot5/ai4	
 | 
			
		||||
st3            	2 6 9	     1	1.450000E-2	kPa	0.000	112A22-19126   	PXI1Slot2/ai6	
 | 
			
		||||
at1            	3 0 9	     1	1.443000E-2	kPa	0.000	112A22-35098   	PXI1Slot3/ai0	
 | 
			
		||||
at2            	3 1 9	     1	1.450000E-2	kPa	0.000	112A22-9050    	PXI1Slot3/ai1	
 | 
			
		||||
at3            	3 2 9	     1	1.447980E-2	kPa	0.000	112A22-19124   	PXI1Slot3/ai2	
 | 
			
		||||
at4            	3 3 9	     1	1.435000E-2	kPa	0.000	112A22-34424   	PXI1Slot3/ai3	
 | 
			
		||||
at5            	3 4 9	     1	1.447000E-2	kPa	0.000	112A22-34425   	PXI1Slot3/ai4	
 | 
			
		||||
at6            	3 5 9	     1	1.442000E-2	kPa	0.000	112A22-34426   	PXI1Slot3/ai5	
 | 
			
		||||
at7            	2 7 9	     1	1.451000E-2	kPa	0.000	112A22-35096   	PXI1Slot2/ai7	
 | 
			
		||||
at8            	3 7 9	     1	1.490000E-2	kPa	0.000	112A22-35079   	PXI1Slot3/ai7	
 | 
			
		||||
pimax4         	5 1 9	     1	1.000000E-3	mV	0.000	pimax4         	PXI1Slot5/ai1	
 | 
			
		||||
trigbox        	5 7 9	     1	1.000000E-3	mV	0.000	trigbox        	PXI1Slot5/ai7(Trigger)	
 | 
			
		||||
trigbox_delay  	5 5 9	     1	1.000000E-3	mV	0.000	trigbox_delay  	PXI1Slot5/ai5	
 | 
			
		||||
pt1            	5 2 9	     1	8.500000E-4	kPa	0.000	SN-22554       	PXI1Slot5/ai2	
 | 
			
		||||
irc800         	8 4 9	     1	1.000000E-3	mV	0.000	irc800         	PXI1Slot8/ai4	
 | 
			
		||||
shimadzu       	8 6 9	     1	1.000000E-3	mV	0.000	shimadzu       	PXI1Slot8/ai6	
 | 
			
		||||
pimax3         	8 7 9	     1	1.000000E-3	mV	0.000	pimax3         	PXI1Slot8/ai7	
 | 
			
		||||
Phantom        	8 2 9	     1	1.000000E-3	mV	0.000	phantom        	PXI1Slot8/ai2	
 | 
			
		||||
pt2            	6 1 9	     1	1.440000E-3	kPa	0.000	SN 22556       	PXI1Slot6/ai1	
 | 
			
		||||
pt3            	6 2 9	     1	1.810000E-3	kPa	0.000	SN 7446        	PXI1Slot6/ai2	
 | 
			
		||||
pt4            	6 3 9	     1	7.300000E-4	kPa	0.000	SN LW30649     	PXI1Slot6/ai3	
 | 
			
		||||
pt5            	8 3 9	     1	7.350000E-4	kPa	0.000	SN LW30651     	PXI1Slot8/ai3	
 | 
			
		||||
pt6            	6 5 9	     1	7.290000E-4	kPa	0.000	SN LW30652     	PXI1Slot6/ai5	
 | 
			
		||||
pt7            	6 6 9	     1	7.220000E-4	kPa	0.000	SN 22514       	PXI1Slot6/ai6	
 | 
			
		||||
pt8            	3 6 9	     1	1.430000E-3	kPa	0.000	SN 16785       	PXI1Slot3/ai6	
 | 
			
		||||
pt9            	5 0 9	     1	1.010000E-3	kPa	0.000	SN 7430        	PXI1Slot5/ai0	
 | 
			
		||||
photodiode     	8 0 9	     1	1.000000E+0	mV	0.000	photodiode     	PXI1Slot8/ai0	
 | 
			
		||||
phantom_aperture	4 4 9	     1	1.000000E-3	mV	0.000	phantom_aperture	PXI1Slot4/ai4	
 | 
			
		||||
							
								
								
									
										20024
									
								
								data/x2s5829/x2s5829.lvm
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										20024
									
								
								data/x2s5829/x2s5829.lvm
									
									
									
									
									
										Normal file
									
								
							
										
											
												File diff suppressed because it is too large
												Load Diff
											
										
									
								
							
							
								
								
									
										
											BIN
										
									
								
								data/x2s5829/x2s5829.tdms
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										
											BIN
										
									
								
								data/x2s5829/x2s5829.tdms
									
									
									
									
									
										Normal file
									
								
							
										
											Binary file not shown.
										
									
								
							
							
								
								
									
										
											BIN
										
									
								
								data/x2s5829/x2s5829.tdms_index
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										
											BIN
										
									
								
								data/x2s5829/x2s5829.tdms_index
									
									
									
									
									
										Normal file
									
								
							
										
											Binary file not shown.
										
									
								
							
							
								
								
									
										161
									
								
								data/x2s5829/x2s5829.txt
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										161
									
								
								data/x2s5829/x2s5829.txt
									
									
									
									
									
										Normal file
									
								
							@@ -0,0 +1,161 @@
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
Project.........................................Mars entry non-equilibrium expanding flows
 | 
			
		||||
Run number................................ x2s5828
 | 
			
		||||
Date............................................16/10/2024
 | 
			
		||||
Blame...........................................Mragank, James 
 | 
			
		||||
Condition................................... Mars condition, high density, Mars mixture
 | 
			
		||||
Reservoir.....................................  6.75 MPa
 | 
			
		||||
Driver............................................83520 Pa 90% He, 92.8 kPa Argon
 | 
			
		||||
Primary diaphragm.................... 2 mm scored, cold rolled steel 6U374
 | 
			
		||||
Shock tube................................... 62308 Pa ( pure co2)
 | 
			
		||||
Secondary diaphragm................  10 micron mylar
 | 
			
		||||
Acceleration tube....................... 250 Pa lab air (set on new gauge on the bottom of the dump tank)
 | 
			
		||||
Trig.............................................. Pt5 (changed as wedge is ahead of pitot probes) slot8ai3 on tee piece 8ai4 - cable pt5
 | 
			
		||||
Lab environment...................... N/A
 | 
			
		||||
Driver Condition........................x2-lwp-2.0-90-0
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
EXPERIMENT SETUP
 | 
			
		||||
 | 
			
		||||
pitot rake
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
EQUIPMENT
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
 | 
			
		||||
1x photodiode (350 - 1100nm)
 | 
			
		||||
1xShimadzu -- in use
 | 
			
		||||
1xmini-spec (200-1000nm)
 | 
			
		||||
Phantom
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
-------------------------- SUSS Spectral Overview ----------------------------
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
Dichroic 1 (UV/VIS):  DMLP650L
 | 
			
		||||
Dichroic 2 (VIS/IR): DMLP900L
 | 
			
		||||
UV FOV: 8mm 
 | 
			
		||||
VIS FOV: 8mm
 | 
			
		||||
IR FOV: 8mm
 | 
			
		||||
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
---UV---
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
N/A
 | 
			
		||||
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
---Visible---
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
Spectrometer: Acton Spectrapro 2300i
 | 
			
		||||
Centre Wavelength: 775
 | 
			
		||||
Grating: 150
 | 
			
		||||
Camera: PIMAX4
 | 
			
		||||
Gain: 50
 | 
			
		||||
Delay: 80 us
 | 
			
		||||
Exposure:  50 us
 | 
			
		||||
Trigger level: 1V
 | 
			
		||||
Slit:  100 um
 | 
			
		||||
Filter: 
 | 
			
		||||
Trigger: A3 cable  from trigger box port 0
 | 
			
		||||
Monitor: T1 Cable 
 | 
			
		||||
Aperture:  12.5 mm
 | 
			
		||||
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
---IR---
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
Spectrometer: Acton Spectrapro 2500
 | 
			
		||||
Centre Wavelength: 1300
 | 
			
		||||
Grating: 75
 | 
			
		||||
Camera: IRC800
 | 
			
		||||
Delay:  100us setted in DAQ with 800 counts
 | 
			
		||||
Exposure:  20 us
 | 
			
		||||
Slit:  1000 um
 | 
			
		||||
Filter: 
 | 
			
		||||
Trigger: T2 cable from trigger box port1
 | 
			
		||||
Monitor: PDTP1G Cable 
 | 
			
		||||
Aperture: 12.5 mm
 | 
			
		||||
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
Shimadzu
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
 | 
			
		||||
Window : BK7 Diam 209mm top
 | 
			
		||||
Lens: Nikon AF Micro NIKKOR 200MM  with 780-unknown? filter
 | 
			
		||||
Aperture-Number 16
 | 
			
		||||
Frame Rates 500.000  kFPS 
 | 
			
		||||
Exposure: 1/2
 | 
			
		||||
Gain: x2(/x50) 
 | 
			
		||||
Mode: External
 | 
			
		||||
Trigger @:  0/0 (0-99=100frames)
 | 
			
		||||
point: 10
 | 
			
		||||
Delay: 0 microseconds
 | 
			
		||||
Polarity: Pos
 | 
			
		||||
Monitor Expose: off
 | 
			
		||||
Filter:
 | 
			
		||||
Cables: Trigger: H6 cable from trigger box port 1
 | 
			
		||||
Monitor: H4 Cable
 | 
			
		||||
 
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
PHOTODIODE 
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
Location:                    Circle around stagnation point, pt5. 
 | 
			
		||||
Filter:                          777nm hydrogen filter actually. not sure which one...
 | 
			
		||||
Model number:         (350-1100)
 | 
			
		||||
Lens:                           Unknown
 | 
			
		||||
Gain:                           70
 | 
			
		||||
Fibre optic cable:      Red
 | 
			
		||||
Aperture:                    None
 | 
			
		||||
BNC:                           A4 
 | 
			
		||||
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
MINI-SPEC (200 - 1000nm)
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
Location: Pt5 looking out into the flow
 | 
			
		||||
Filter: none
 | 
			
		||||
Window: 3mm fused silica from OGP optics.
 | 
			
		||||
Cable: New red cable
 | 
			
		||||
Lens: N/A
 | 
			
		||||
Delay: 80 us + 8 us internal 
 | 
			
		||||
Integration time: 20 us
 | 
			
		||||
Aperture: N/A
 | 
			
		||||
Trigger level: 1 V
 | 
			
		||||
Filter: N/A 
 | 
			
		||||
Trigger: A5 cable from trigger box port 0, with vis
 | 
			
		||||
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
Phantom
 | 
			
		||||
--------------------------------------------------------------------------------
 | 
			
		||||
 | 
			
		||||
Window : side
 | 
			
		||||
Lens: Nikon AF Micro NIKKOR 105 mm focus
 | 
			
		||||
Aperture-Number 11
 | 
			
		||||
Frame Rates 110000.000  FPS 
 | 
			
		||||
Exposure: 1 us
 | 
			
		||||
Gain: N/A
 | 
			
		||||
Mode: External
 | 
			
		||||
Delay: 0 microseconds
 | 
			
		||||
Polarity: Pos
 | 
			
		||||
Monitor Expose: off
 | 
			
		||||
Filter:
 | 
			
		||||
Cables: Trigger: B3 cable from trigger box port 2
 | 
			
		||||
Monitor: H4 Cable
 | 
			
		||||
 
 | 
			
		||||
 | 
			
		||||
UV phantom as well 
 | 
			
		||||
 | 
			
		||||
LOG
 | 
			
		||||
X2s5815
 | 
			
		||||
Bad shot - very messy - oring ruptured in the secondary may have over pressurised with additional  LAB Air.
 | 
			
		||||
X2s5816
 | 
			
		||||
Fired at 1.32Pa instead of 13.2pa.....
 | 
			
		||||
x2s5826
 | 
			
		||||
Phantom aperture was 18 in description for prev shot but was set to 22 for the prev shot
 | 
			
		||||
Phantom trig signal changed from falling to rising
 | 
			
		||||
 | 
			
		||||
		Reference in New Issue
	