Project.............................. Yu Liu -- Gas giant Neon condition Run number........................... x2s4111 Date................................. 13/10/2018 Blame................................ Yu Liu, Chris James Reservoir........................... 4.85 MPa compressed air Driver............................... 80% He,20% Ar filled to 1103 mba. Flushed twice with He Primary diaphragm.................... 1.2 mm hot rolled steel scored diaphragm Shock tube........................... 2000 Pa 80% Ne, 20% H2 by volume, flushed twice with He Secondary diaphragm.................. 12 micron Al Acceleration tube.................... 1 Pa lab air Trig................................. Triggering off pt2, trigger level set to 5 on box EXPERIMENT Gas Giant Helium condition. Centre IR 1500 nm Centre UV 525 nm High speed camera in use --------------------- -- UV spectrometer -- --------------------- Centre wavelength = 525 nm Aperture = 20 mm Delay = 200 us Exposure = 20 us Slit width = 50 um Filter = 400 nm longpass filter Gain: 2800 Grating: 150 --------------------- -- IR spectrometer -- --------------------- Centre wavelength = 1500 nm Aperture = 20 mm Delay = triggering off Andor Exposure = 20 us Slit width = 250 um Filter = 850 nm longpass filter FGL850S, I think ----------------------- -- High speed camera -- ----------------------- Andover corp H-beta filter f-number: 8 Framerate: 250 kHz (4 us between frames) Exposure : 1/2 Pre-frames = 10 Delay = 0 us Gain: 2 ----------------------- -- Thermocouple mount - ----------------------- Channel: 1 Gain: 100 Resistance 3.6 - 3.7 Ohms (may change slightly from shot to sjot, but being checked... New thermocouple with ground wire