# x2s4111 config file # This files contains a text version of the National Instruments PXI unit configuration data. # Channels are represented as one line per configured signal with tab-separated values. # # Line content and types of values (first item is item 0): # i item type comments # -------------------------------------------------------------------------------------------------------- # 0 signal name string # 1 channel ID string legacy I/O channel designation # 2 external gain float 1 if there is no external amplifier connected # 3 sensitivity float volts per measured unit (of the transducer) # 4 units string name of units for physical quantity (e.g. kPa) # 5 position float position of transducer (in mm) # 6 serial number string transducer identity # 7 PXI channel ID string non-legacy channel ID and trigger source #--------------------------------------------------------------------------------------------------------- sd1 2 0 9 1 7.321500E-4 kPa 0.000 113B24-LW30646 PXI1Slot2/ai0 -1.000 1.000 sd2 2 7 9 1 7.259100E-4 kPa 0.000 113B24-LW30648 PXI1Slot2/ai7 -1.000 1.000 sd3 2 2 9 1 6.820000E-4 kPa 0.000 112A24-2676 PXI1Slot2/ai2 -1.000 1.000 st1 5 2 9 1 1.239800E-2 kPa 0.000 112A24-9594 PXI1Slot5/ai2 -1.000 1.000 st2 2 4 9 1 1.187400E-2 kPa 0.000 112A24-19126 PXI1Slot2/ai4 -1.000 1.000 st3 2 5 9 1 1.482000E-2 kPa 0.000 112A24-35071 PXI1Slot2/ai5 -1.000 1.000 at1 3 0 9 1 1.443000E-2 kPa 0.000 112A22-35098 PXI1Slot3/ai0 -1.000 1.000 at2 3 1 9 1 1.450000E-2 kPa 0.000 112A22-9050 PXI1Slot3/ai1 -1.000 1.000 at3 3 2 9 1 1.447980E-2 kPa 0.000 112A22-19124 PXI1Slot3/ai2 -1.000 1.000 at4 3 3 9 1 1.435000E-2 kPa 0.000 112A22-34424 PXI1Slot3/ai3 -1.000 1.000 at5 3 4 9 1 1.393600E-2 kPa 0.000 112A22-35042 PXI1Slot3/ai4 -1.000 1.000 at6 3 5 9 1 1.442000E-2 kPa 0.000 112A22-34426 PXI1Slot3/ai5 -1.000 1.000 at7 3 6 9 1 1.451000E-2 kPa 0.000 112A22-35096 PXI1Slot3/ai6 -1.000 1.000 at8 3 7 9 1 1.490000E-2 kPa 0.000 112A22-35079 PXI1Slot3/ai7 -1.000 1.000 trigbox 5 0 9 1 1.000000E-3 mV 0.000 trigbox PXI1Slot5/ai0(Trigger) -10.000 10.000 photodiode 5 1 9 1 1.000000E-3 mV 0.000 photodiode PXI1Slot5/ai1 -10.000 10.000 hpv1 5 6 9 1 1.100000E-3 mV 0.000 hpv1 PXI1Slot5/ai6 -10.000 10.000 pt1 4 0 9 1 1.464000E-2 kPa 0.000 112A22-36656 PXI1Slot4/ai0 -10.000 10.000 pt2 4 1 9 1 1.212200E-2 kPa 0.000 112A22-35073 PXI1Slot4/ai1 -10.000 10.000 pt3 4 2 9 1 1.448000E-2 kPa 0.000 112A22-36657 PXI1Slot4/ai2 -10.000 10.000 mwirout 5 7 9 1 1.000000E-3 mV 0.000 mwirout PXI1Slot5/ai7 -10.000 10.000 tctest 5 3 9 1 1.000000E-3 mV 0.000 tctest PXI1Slot5/ai3 -5.000 5.000 uvout 5 4 9 1 1.000000E-3 mV 0.000 uvout PXI1Slot5/ai4 -10.000 10.000