Project.........................................Mars entry non-equilibrium expanding flows
Run number................................ x2s5820
Date............................................10/10/2024
Blame...........................................Mragank, Matt
Condition................................... Mars condition, high density, Mars mixture
Reservoir..................................... 6.75 MPa
Driver............................................83520 Pa 90% He, 92.8 kPa Argon
Primary diaphragm.................... 2 mm scored, cold rolled steel 6U374
Shock tube................................... 13000 Pa ( Mars mixture)
Secondary diaphragm................ 10 micron mylar
Acceleration tube....................... 650 Pa lab air (set on new gauge on the bottom of the dump tank)
Trig.............................................. Pt5 (changed as wedge is ahead of pitot probes) slot8ai3 on tee piece 8ai4 - cable pt5
Lab environment...................... N/A
Driver Condition........................x2-lwp-2.0-90-0
--------------------------------------------------------------------------------
EXPERIMENT SETUP
pitot rake
--------------------------------------------------------------------------------
EQUIPMENT
--------------------------------------------------------------------------------
1x photodiode (350 - 1100nm)
1xShimadzu -- in use
1xmini-spec (200-1000nm)
Phantom
-------------------------- SUSS Spectral Overview ----------------------------
--------------------------------------------------------------------------------
Dichroic 1 (UV/VIS): DMLP650L
Dichroic 2 (VIS/IR): DMLP900L
UV FOV: 8mm
VIS FOV: 8mm
IR FOV: 8mm
--------------------------------------------------------------------------------
---UV---
--------------------------------------------------------------------------------
Spectrometer: Acton Spectrapro 2300i
Centre Wavelength: 430
Grating: 150
Camera: PIMAX3
Gain: 60
Delay: 45 us
Exposure: 20 us
Trigger level: 1 V
Slit: 100 um
Filter: N/A
Trigger: A5 cable from trigger box port 0
Monitor: DB1 Cable
Phosphor decay delay: default
Phsophor decal resolution: default
Aperture::12.5 mm
--------------------------------------------------------------------------------
---Visible---
--------------------------------------------------------------------------------
Spectrometer: Acton Spectrapro 2300i
Centre Wavelength: 775
Grating: 150
Camera: PIMAX4
Gain: 50
Delay: 45 us
Exposure: 20 us
Trigger level: 1V
Slit: 100 um
Filter:
Trigger: A3 cable from trigger box port 0
Monitor: T1 Cable
Aperture: 12.5 mm
--------------------------------------------------------------------------------
---IR---
--------------------------------------------------------------------------------
Spectrometer: Acton Spectrapro 2500
Centre Wavelength: 1300
Grating: 75
Camera: IRC800
Delay: 105us setted in DAQ with 320 counts
Exposure: 20 us
Slit: 1000 um
Filter:
Trigger: T2 cable from trigger box port1
Monitor: PDTP1G Cable
Aperture: 12.5 mm
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Shimadzu
--------------------------------------------------------------------------------
Window : BK7 Diam 209mm top
Lens: Nikon AF Micro NIKKOR 200MM with 780-unknown? filter
Aperture-Number 16
Frame Rates 500.000 kFPS
Exposure: 1/2
Gain: x2(/x50)
Mode: External
Trigger @: 0/0 (0-99=100frames)
point: 10
Delay: 0 microseconds
Polarity: Pos
Monitor Expose: off
Filter:
Cables: Trigger: H6 cable from trigger box port 2
Monitor: H4 Cable
--------------------------------------------------------------------------------
PHOTODIODE
--------------------------------------------------------------------------------
N/A
--------------------------------------------------------------------------------
MINI-SPEC (200 - 1000nm)
--------------------------------------------------------------------------------
N/A
LOG
X2s5815
Bad shot - very messy - oring ruptured in the secondary may have over pressurised with additional LAB Air.
X2s5816
Fired at 1.32Pa instead of 13.2pa.....