Project.........................................Mars entry non-equilibrium expanding flows
Run number................................ x2s5827
Date............................................16/10/2024
Blame...........................................Mragank, Matt, Chengxin, Sam
Condition................................... Mars condition, high density, Mars mixture
Reservoir..................................... 6.75 MPa
Driver............................................83520 Pa 90% He, 92.8 kPa Argon
Primary diaphragm.................... 2 mm scored, cold rolled steel 6U374
Shock tube................................... 62308 Pa ( Mars mixture)
Secondary diaphragm................ 10 micron mylar
Acceleration tube....................... 250 Pa lab air (set on new gauge on the bottom of the dump tank)
Trig.............................................. Pt5 (changed as wedge is ahead of pitot probes) slot8ai3 on tee piece 8ai4 - cable pt5
Lab environment...................... N/A
Driver Condition........................x2-lwp-2.0-90-0
--------------------------------------------------------------------------------
EXPERIMENT SETUP
pitot rake
--------------------------------------------------------------------------------
EQUIPMENT
--------------------------------------------------------------------------------
1x photodiode (350 - 1100nm)
1xShimadzu -- in use
1xmini-spec (200-1000nm)
Phantom
-------------------------- SUSS Spectral Overview ----------------------------
--------------------------------------------------------------------------------
Dichroic 1 (UV/VIS): DMLP650L
Dichroic 2 (VIS/IR): DMLP900L
UV FOV: 8mm
VIS FOV: 8mm
IR FOV: 8mm
--------------------------------------------------------------------------------
---UV---
--------------------------------------------------------------------------------
N/A
--------------------------------------------------------------------------------
---Visible---
--------------------------------------------------------------------------------
Spectrometer: Acton Spectrapro 2300i
Centre Wavelength: 775
Grating: 150
Camera: PIMAX4
Gain: 50
Delay: 80 us
Exposure: 50 us
Trigger level: 1V
Slit: 100 um
Filter:
Trigger: A3 cable from trigger box port 0
Monitor: T1 Cable
Aperture: 12.5 mm
--------------------------------------------------------------------------------
---IR---
--------------------------------------------------------------------------------
Spectrometer: Acton Spectrapro 2500
Centre Wavelength: 1300
Grating: 75
Camera: IRC800
Delay: 100us setted in DAQ with 800 counts
Exposure: 20 us
Slit: 1000 um
Filter:
Trigger: T2 cable from trigger box port1
Monitor: PDTP1G Cable
Aperture: 12.5 mm
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Shimadzu
--------------------------------------------------------------------------------
Window : BK7 Diam 209mm top
Lens: Nikon AF Micro NIKKOR 200MM with 780-unknown? filter
Aperture-Number 16
Frame Rates 500.000 kFPS
Exposure: 1/2
Gain: x2(/x50)
Mode: External
Trigger @: 0/0 (0-99=100frames)
point: 10
Delay: 0 microseconds
Polarity: Pos
Monitor Expose: off
Filter:
Cables: Trigger: H6 cable from trigger box port 1
Monitor: H4 Cable
--------------------------------------------------------------------------------
PHOTODIODE
--------------------------------------------------------------------------------
Location: Circle around stagnation point, pt5.
Filter: 777nm hydrogen filter actually. not sure which one...
Model number: (350-1100)
Lens: Unknown
Gain: 70
Fibre optic cable: Red
Aperture: None
BNC: A4
--------------------------------------------------------------------------------
MINI-SPEC (200 - 1000nm)
--------------------------------------------------------------------------------
Location: Pt5 looking out into the flow
Filter: none
Window: 3mm fused silica from OGP optics.
Cable: New red cable
Lens: N/A
Delay: 80 us + 8 us internal
Integration time: 20 us
Aperture: N/A
Trigger level: 1 V
Filter: N/A
Trigger: A5 cable from trigger box port 0, with vis
--------------------------------------------------------------------------------
Phantom
--------------------------------------------------------------------------------
Window : side
Lens: Nikon AF Micro NIKKOR 105 mm focus
Aperture-Number 11
Frame Rates 110000.000 FPS
Exposure: 1 us
Gain: N/A
Mode: External
Delay: 0 microseconds
Polarity: Pos
Monitor Expose: off
Filter:
Cables: Trigger: B3 cable from trigger box port 2
Monitor: H4 Cable
UV phantom as well
LOG
X2s5815
Bad shot - very messy - oring ruptured in the secondary may have over pressurised with additional LAB Air.
X2s5816
Fired at 1.32Pa instead of 13.2pa.....
x2s5826
Phantom aperture was 18 in description for prev shot but was set to 22 for the prev shot
Phantom trig signal changed from falling to rising